Z-Wave Nodon Soft Remote

.

در جدول زیر پارامترهای ریموت کنترل سافت نودان معرفی شده است:

.

Parameter Number

Parameter Size Parameter Name

Parameter Values

1

1 Buttons 1 & 3 Profile 0
(Default)

SCENE. Product sends “Central Scene Notification” Commands or “Scene Activation” Commands.

1

MONO. Button 1 is not paired with button 3.

2

DUO. Button 1 is paired with button 3.

2

1 Buttons 2 & 4 Profile 0
(Default)

SCENE. Product sends “Central Scene Notification” Commands or “Scene Activation” Commands.

1

MONO. Button 1 is not paired with button 3.

2

DUO. Button 1 is paired with button 3.

3

1 Scene Type 0
(Default)

Use “CENTRAL SCENE” Commands.

1

Use “SCENE ACTIVATION” Commands.

4

1 Button 1 Configuration 0
(Default)

Single Press sends “Basic Set” Command to associated devices in Group 2.

1

Single Press sends broadcast “Switch All On” Command.

2

Single Press sends broadcast “Switch All Off” Command.

5

1 Button 2 Configuration 0
(Default)

Single Press sends “Basic Set” Command to associated devices in Group 3.

1

Single Press sends broadcast “Switch All On” Command.

2

Single Press sends broadcast “Switch All Off” Command.

6

1 Button 3 Configuration 0
(Default)

Single Press sends “Basic Set” Command to associated devices in Group 4.

1

Single Press sends broadcast “Switch All On” Command.

2

Single Press sends broadcast “Switch All Off” Command.

7

1 Button 4 Configuration 0
(Default)

Single Press sends “Basic Set” Command to associated devices in Group 5.

1 Single Press sends broadcast “Switch All On” Command.
2

Single Press sends broadcast “Switch All Off” Command.

8

1 Led Management 3 Combined behaviors of 0x01 and 0x02 modes.
0
(Default)
Led does not acknowledge button action and does not acknowledge result of radio command sent.
1

When the end-user performs a Single press, Double press or Hold Press on a button, led blinks blue to acknowledge the button action.

2

When the end-user sends a controlled command: “Basic Set” Command or “Central Scene Notification” Command or “Multilevel Switch Stop Level Change” Command. Led blinks GREEN to acknowledge transmission success or blinks RED to acknowledge transmission failed.